A Study on the Effect of Solar Fraction on the Environmental Performance of Solar Air-Conditioning by an Adsorption Chiller

Authors

  • F. Basrawi Universiti Malaysia Pahang
  • K. Habib University Technology Petronas
  • H. Ibrahim Universiti Malaysia Pahang
  • G.C. Lee Universiti Malaysia Pahang

DOI:

https://doi.org/10.15377/2409-5818.2015.02.01.3

Keywords:

Solar cooling, adsorption chiller, solar fraction, emissions.

Abstract

Solar air-conditioning (AC) is a sustainable air-conditioning system but a back-up heater is needed because a solar AC has intermittent output. This study presents the effect of ratio of heat delivered by solar to the total heat delivered to an adsorption chiller (solar fraction) on the environmental performance of a solar AC system. This AC system need covers cooling demand for an office building in Malaysia. Cooling demand of the building was simulated using well-known building energy analysis software, Equest. Flat-plate collectors and an adsorption chiller were the main component of the solar AC system. Flat-plate collecters were simulated using another software, Watsun, and the adsorption chiller was based on the author simulation model that is comparable with other studies. Environmental performance was analyzed by emission ratio of a boiler and power plants. Solar fraction of 0.33, 0.74 and 0.98 were studied. It was found that solar AC by an adsorption chiller can cover the cooling demand of the office building throughout the year. It was also found that a gas fired boiler is a better auxiliary heater than an electric heater because of the direct conversion of heat from fuel. Less emissions is emited at higher SF compared to conventional AC for all cases of back-up heater. A solar AC must has solar fraction higher than 74% to ensure it emits less emissions than a conventional AC system.

Author Biographies

  • F. Basrawi, Universiti Malaysia Pahang
    Mechanical Engineering
  • K. Habib, University Technology Petronas
    Mechanical Engineering
  • H. Ibrahim, Universiti Malaysia Pahang
    Mechanical Engineering
  • G.C. Lee, Universiti Malaysia Pahang
    Mechanical Engineering

References

GK. Qian S, Hwang Y, Rademacher R, Chun H. Cyclic steady state performance of adsorption chiller with low regeneration temperature zeolite. Energy 2013; 60: 517-526. http://dx.doi.org/10.1016/j.energy.2013.08.041 DOI: https://doi.org/10.1016/j.energy.2013.08.041

RK. Ahmed RMR. Physical and operating conditions effects on silica gel/water adsorption chiller performance. Applied Energy 2012; 89: 921-929. DOI: https://doi.org/10.1016/j.apenergy.2010.11.021

IS. Yuriy IA, Ilya SG, Lambert MA, Beyene A. Optimization of adsorption dynamics in adsorptive chillers: Loose grains configuration. Energy 2012; 46: 484-492. http://dx.doi.org/10.1016/j.energy.2012.08.001 DOI: https://doi.org/10.1016/j.energy.2012.08.001

TH. Hamid N, Mahdavikhah M. Bed geometrical specifications effects on the performance of silica/water adsorption chillers. International Journal of Refrigeration 2012; 35: 2261-2274. http://dx.doi.org/10.1016/j.ijrefrig.2012.08.017 DOI: https://doi.org/10.1016/j.ijrefrig.2012.08.017

WR. Lu ZS, Xia ZZ, Lu XR, Yang CB, Ma YC, Ma GB. Study of a novel solar adsorption cooling system and a solar absorption cooling system with new CPC collectors. Renewable Energy 2013; 50: 299-306. http://dx.doi.org/10.1016/j.renene.2012.07.001 DOI: https://doi.org/10.1016/j.renene.2012.07.001

MJ. Spencer JD, Gibbons WT, Gluesenkamp K, Ahmed II, Tavemer AM, McGahagan D, Tesfaye M, Gupta C, Boume RP, Monje V, Jackson GS. Design of a combined heat, hydrogen, and power plant from university campus waste streams. International Journal of Hydrogen Energy 2013; 39: 4889-4900. http://dx.doi.org/10.1016/j.ijhydene.2013.02.021 DOI: https://doi.org/10.1016/j.ijhydene.2013.02.021

FA. Strachan N. Emissions from distributed vs. centralized generation: The importance of system performance. Energy Policy 2006; 34: 2677-2689. http://dx.doi.org/10.1016/j.enpol.2005.03.015 DOI: https://doi.org/10.1016/j.enpol.2005.03.015

Downloads

Published

2015-04-01

Issue

Section

Articles

How to Cite

1.
A Study on the Effect of Solar Fraction on the Environmental Performance of Solar Air-Conditioning by an Adsorption Chiller. Glob. J. Energy. Technol. Res. Updates. [Internet]. 2015 Apr. 1 [cited 2026 Feb. 16];2(1):19-24. Available from: https://www.avantipublishers.com/index.php/gjetru/article/view/192

Similar Articles

11-20 of 32

You may also start an advanced similarity search for this article.